skip to Main Content
Welcome to our Frequently Asked Questions (FAQs) page, where we address the most common questions about each of our brands. Whether you're seeking information about our products, services, or support, you’ll find comprehensive answers tailored to your needs.

Feel free to browse through each section to find the information you need. If you have further questions, our support team is always here to help!

Metzeler Mattresses

Explore our range of pressure care mattresses and find answers to questions on product specifications, care instructions, and the best options for individual needs.

Cura Seating

Gain insights into our advanced seating solutions designed for comfort, support, and enhanced mobility. Get information on product features, maintenance tips, and customization services.

Mountain Trike

Discover all-terrain solutions designed for maximum mobility and independence. Learn about our innovative trikes, customization options, and support services.

COBI Rehab

Explore a specialised range of bariatric products, offering innovative mobility and hygiene solutions tailored to individual needs. Designed to provide enhanced comfort, support, and freedom.

WinnCare

Learn more about our healthcare solutions, including patient lifting equipment, and find answers to your inquiries regarding product use, safety guidelines, and after-sales support.

Finch Resources

Document archive of Finch product reference and resource material is available here. PDF downloads available including brochures, manuals and product information.

FOR PROFESSIONAL DEVELOPMENT & TRAINING CONTACT US TODAY

Pure Air 8 Acute Mattress

The Pure Air 8 Acute Mattress is a fully automatic, high-performance dynamic pressure-relieving system designed to support patients at very high risk of pressure injuries, including those with existing Stage I–IV wounds. Engineered for acute care environments, it combines intelligent alternating pressure therapy with responsive foam support to deliver clinically proven pressure redistribution, optimal patient comfort, and exceptional ease of use for caregivers.

The Pure Air 8 Acute Mattress is a fully automatic, high-performance dynamic pressure-relieving system designed to support patients at very high risk of pressure injuries, including those with existing Stage I–IV wounds. Engineered for acute care environments, it combines intelligent alternating pressure therapy with responsive foam support to deliver clinically proven pressure redistribution, optimal patient comfort, and exceptional ease of use for caregivers.

This advanced system features eight horizontal air cells, each working in tandem through a dynamic 1-in-2 alternating cycle. The alternating sequence gently offloads tissue pressure in 10-minute cycles, reducing sustained pressure on vulnerable areas such as the sacrum, heels, and shoulders. These quiet, dynamic shifts in support mimic natural movement, helping stimulate blood flow and support tissue viability — critical for wound prevention and healing.

The mattress also includes a viscoelastic foam topper, which enhances immersion and envelopment of the body into the surface. This foam layer reduces shear and friction while maintaining a soft, comfortable feel — especially important for patients with frail or fragile skin. The combination of air cell movement and foam contouring offers a dual-action pressure care approach, delivering high levels of clinical protection.

The digital pump unit offers fully automated functionality, adjusting internal pressures based on patient weight and positioning with no need for manual input. This makes the Pure Air 8 ideal for fast-paced care environments where staff efficiency and therapeutic reliability are essential. The pump also includes an Auto-Firm mode to assist with patient transfers and nursing procedures, as well as a seat inflation mode for use when the backrest is elevated — helping to maintain pressure relief when patients are sitting up in bed.

Built-in visual and audible alarms alert carers to any issues such as low pressure or power failure, ensuring safety is prioritised at all times. The system also features an emergency CPR release valve for rapid deflation in urgent scenarios, and a transport mode to keep the mattress inflated during short patient transfers without power.

The mattress cover is made from a vapour-permeable, waterproof, 4-way stretch material that aids in moisture management and infection control. It is easy to clean, remove, and launder at high temperatures (up to 95°C), supporting hospital-grade hygiene standards.

Designed with durability and flexibility in mind, the Pure Air 8 Acute is suitable for both hospital beds and community care settings, and can accommodate a wide range of patient profiles. It supports safe patient weights of up to 200kg.

Features

  • Dynamic alternating pressure with 8-cell horizontal layout (1-in-2 cycle)

  • 10-minute cycle time for continuous pressure redistribution

  • Viscoelastic foam topper for added comfort, immersion, and shear reduction

  • Auto weight-sensing pump with digital control — no manual calibration required

  • Seat inflation and Auto-Firm modes to assist with repositioning and seated care

  • Visual and audible low-pressure, power failure, and service alarms

  • CPR quick-release function and transport mode

  • Vapour-permeable, waterproof, 4-way stretch top cover

  • Suitable for users up to 200kg

  • Ideal for acute care, post-operative patients, palliative care, and complex wound management

The Pure Air 8 Acute represents the gold standard in dynamic mattress systems, combining intelligent pressure relief technology with comfort-enhancing materials and reliable safety features. Whether in hospital, rehabilitation, or complex community care environments, this mattress delivers superior outcomes in wound prevention, healing, and patient comfort — while reducing the workload on busy care teams.

 For patients identified as being very high risk of developing a pressure ulcer, Pure Air 8
Acute is a full replacement dynamic mattress for the most demanding of clinical environments including ITU,  acute wards and community care.

Product Code:  SM013A

Surface Type: Dynamic (Active)

Therapy: Alternating, CLP, Pulsation, Max

Inflate Maximum User Weight: 250 kg (39 stone)

Risk Category: Very high

Warranty: 3 year

Dimensions

Mattress Size Firmness Dimensions Product Code
Single Medium 900x2000x180mm 729595-ADM090
Single Soft 900x2000x180mm 732758-ADS090
King Single Medium 1050x2000x180mm 729611-ADM105
King Single Soft 1050x2000x180mm 732757-ADS105
Double Medium 1350x2000x180mm 721972-ADM135
Queen Medium 1520x2000x180mm 721970-ADM152
Split Queen Medium 760x2000x180mm 721967-ADM076

Mattress Specifications

Feature Details
Dimensions 200 cm (L) x 88 cm (W) x 20 cm (H)
Number of Cells 23 total (3 static head cells, 20 alternating)
Inflated Cell Height 20 cm (8”)
Alternation Cycle 1-in-2
Initial Inflation Time Approx. 20 minutes
Cell Material TPU (Thermoplastic Polyurethane)
Internal Cell Pressure
Alternating Mode 13 – 70 ±2 mmHg
Constant Low Pressure Mode 10 – 40 ±2 mmHg
Pulsation Mode 80% & 120% of CLP setting
Max Inflate 40 ±2 mmHg
Top Cover Multi-stretch Polyurethane
Seams High-frequency welded
Safe Working Load (SWL) >250 kg
CPR Function Easy-turn dial (deflates within 30 seconds)
Cover Cleanability Machine washable up to 95°C
Transport Mode 24-hour capacity via one-way valve

Control Unit Specifications

Feature Details
Dimensions 39 cm (L) x 14.5 cm (W) x 18 cm (H)
Weight 4.1 kg
Max Inflate Auto-return to therapy mode after 20 minutes
Cell Cycle Time Options 10, 15, or 20 minutes
Pressure Adjustment Fully automatic
Noise Level <40 dB(A)
Alerts Audible low-pressure alert with optional mute
Control Panel Lock Yes

Warranties & Standards

ARTG Number: 363471

Warranty:

Mattress Internal Components Three Years
Cover Three Years
Pump Three Years
Clinical Service Life – Normal Use Six Years

Standards:

EMDN Code & Term V080701 Active anti-bedsore medical mattresses
Risk Classification Risk Classification: Class I medical device according to the regulation (EU) 2017/745, Annex
VIII, rule 1
Harmonised Standards Applied EN ISO: 13485:2016, 14971:2012, 15223-1:2016, 10535:2006
Basic UDI-DI 50564619DYN_PUP3N
Quality Management System ISO-13485-2016
Safety Standards BS EB 60601-1:2006+A13:2024
IEC 60601-1-11, IEC 60601-1-2, BS EN 61000, IEC 61000-3-3, IEC 61000-3-2, IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11,
IEC 61000-4-8, IEC 61000-4-6, IEC 61000-4-3
Biocompatibility Standards (Skin & Patient Contact) SO 10993 series — Biological evaluation of medical devices

ISO 10993-1: Evaluation and testing within a risk management process

ISO 10993-5: Tests for in vitro cytotoxicity

ISO 10993-10: Tests for irritation and skin sensitization

ISO 10993-23: Tests for irritation (skin and mucosal surfaces)

Infection Control & Hygiene ISO 16603 / ISO 16604 — Resistance of materials to penetration by blood and body fluids / blood-borne pathogens

EN ISO 22610 — Resistance to wet bacterial penetration (commonly referenced alongside UNI EN 13795)

EN ISO 22612 — Resistance to dry microbial penetration

ISO 14272 (and related) — Cleanability and disinfectant resistance

Flammability Standards (Hospital Safety) BS 7175 — Flammability testing for bed mattresses and components used in hospitals (UK/NHS standard)

Crib 5 / Source 5 test — Specific ignition resistance test (often cited in Australia & UK healthcare tenders)

CAL TB 129 (California Technical Bulletin) — Full-scale flammability test for mattresses

EN 597-1 & EN 597-2 — Smouldering cigarette and match flame tests

Performance & Durability SO 12947 (Martindale Test) — Abrasion resistance of fabrics

ISO 811 — Hydrostatic head test (liquid barrier performance)

ISO 14126 — Protective clothing against infective agents (often adapted for mattress covers in clinical use)

EN 13795 (for surgical textiles, sometimes referenced in infection-barrier bedding)

Resources

WinnCare Resources

 

 

WinnCare product brochures, user guides, certificates and standards, warranties and additional resources and support material available via button link above.

Enquiry

Disclaimer

All product descriptions, indications or advice found on this website are to be used as a guide only, and are by no means a substitute for professional medical advice. Proper use of medical devices requires diagnosis by a physician or physical therapist. Finch Healtchare accepts no responsibility for the improper or uninformed use of it’s products.

 

Back To Top