skip to Main Content
Welcome to our Frequently Asked Questions (FAQs) page, where we address the most common questions about each of our brands. Whether you're seeking information about our products, services, or support, you’ll find comprehensive answers tailored to your needs.

Feel free to browse through each section to find the information you need. If you have further questions, our support team is always here to help!

Metzeler Mattresses

Explore our range of pressure care mattresses and find answers to questions on product specifications, care instructions, and the best options for individual needs.

Cura Seating

Gain insights into our advanced seating solutions designed for comfort, support, and enhanced mobility. Get information on product features, maintenance tips, and customization services.

Mountain Trike

Discover all-terrain solutions designed for maximum mobility and independence. Learn about our innovative trikes, customization options, and support services.

COBI Rehab

Explore a specialised range of bariatric products, offering innovative mobility and hygiene solutions tailored to individual needs. Designed to provide enhanced comfort, support, and freedom.

WinnCare

Learn more about our healthcare solutions, including patient lifting equipment, and find answers to your inquiries regarding product use, safety guidelines, and after-sales support.

Finch Resources

Document archive of Finch product reference and resource material is available here. PDF downloads available including brochures, manuals and product information.

FOR PROFESSIONAL DEVELOPMENT & TRAINING CONTACT US TODAY

Pure Air 120 Mattress

The Pure Air 120 Mattress is a premium dynamic bariatric pressure care system designed for patients at very high risk of pressure injuries, with a safe working load of up to 298 kg. Developed for acute, long-term, and high-dependency care environments, it provides continuous pressure redistribution and stability while addressing the specific challenges of bariatric care.

The Pure Air 120 Mattress is a premium dynamic bariatric pressure care system designed for patients at very high risk of pressure injuries, with a safe working load of up to 298 kg. Developed for acute, long-term, and high-dependency care environments, it provides continuous pressure redistribution and stability while addressing the specific challenges of bariatric care.

The mattress features full-width “Figure of 8” air cells with i-Beam reinforcement, creating a stable, shock-absorbing surface that prevents bottoming out and minimises patient sliding during repositioning or transfers. Combined with intelligent semi-automatic adjustment, the system delivers low interface pressures tailored to patient weight, movement, and clinical needs.

patented alternation cycle ensures smoother, quieter transitions between inflation phases, reducing shear forces and minimising sleep disruption. Configurable cycle times (10 or 15 minutes) allow clinicians to adapt therapy to individual requirements.

The multi-stretch, vapour-permeable cover with high-frequency welded seams supports effective moisture management, infection control, and skin protection. Fully removable and machine washable at 95°C, it meets stringent hygiene protocols across hospital and bariatric care settings.

For safety and efficiency, the Pure Air 120 integrates CPR quick-release, a 24-hour transport mode, and audible low-pressure alarms with a mute function. A panel lock prevents accidental setting changes, ensuring uninterrupted therapy and consistent clinical outcomes.

Features

Key Features:

  • Bariatric dynamic replacement mattress – supports users up to 298 kg.

  • Full-width “Figure of 8” air cells with i-Beam design – provides stability, shock absorption, and prevents bottoming out.

  • Low interface pressure technology – immersion and offloading reduce pressure injury risk in high-risk bariatric patients.

  • Configurable alternation cycle – selectable 10 or 15-minute cycles for tailored therapy.

  • Quiet operation (<40 dB[A]) – minimises patient disturbance, promotes restful sleep.

  • Rapid response features – CPR deflation in under 30 seconds, 24-hour transport mode.

  • Infection control compliant – vapour-permeable, welded cover washable at 95°C.

  • Clinical alarms and safety lock – audible alerts with mute function, control panel lock for therapy adherence.

 

Mattress Specifications

Feature Details
Max User Weight 298 kg
Dimensions 200 cm x 120 cm x 20 cm
Number of Cells 20 alternating
Inflated Cell Height 20 cm
Alternation Cycle 1 in 2
Initial Inflation Time 30 – 40 mins
Cell Material TPU
Internal Cell Pressure 30 – 60 mmHg
Top Cover Multi-stretch polyurethane
Seams High frequency welded
CPR Pull chord (deflates within 30 seconds)
Transport Mode 24 hours via transport cap
Cleaning Machine washable up to 95°C

Control Unit Specifications

Feature Details
Dimensions 23.5 cm x 35.5 cm x 13.5 cm
Weight 3.7 kg
Max Inflate Auto-return to therapy after 30 mins
Cell Cycle Time 10, 15 mins
Pressure Adjustment Semi-automatic
Noise Level <40 dB(A)
Alerts Audible low pressure alert with mute
Control Panel Lock Yes

Warranties & Standards

ARTG Number: 363471

Warranty:

Mattress Internal Components Three Years
Cover Three Years
Pump Three Years
Clinical Service Life – Normal Use Six Years

Standards:

EMDN Code & Term V080701 Active anti-bedsore medical mattresses
Risk Classification Risk Classification: Class I medical device according to the regulation (EU) 2017/745, Annex
VIII, rule 1
Harmonised Standards Applied EN ISO: 13485:2016, 14971:2012, 15223-1:2016, 10535:2006
Basic UDI-DI 50564619DYN_PUP3N
Quality Management System ISO-13485-2016
Safety Standards BS EB 60601-1:2006+A13:2024
IEC 60601-1-11, IEC 60601-1-2, BS EN 61000, IEC 61000-3-3, IEC 61000-3-2, IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11,
IEC 61000-4-8, IEC 61000-4-6, IEC 61000-4-3
Biocompatibility Standards (Skin & Patient Contact) SO 10993 series — Biological evaluation of medical devices

ISO 10993-1: Evaluation and testing within a risk management process

ISO 10993-5: Tests for in vitro cytotoxicity

ISO 10993-10: Tests for irritation and skin sensitization

ISO 10993-23: Tests for irritation (skin and mucosal surfaces)

Infection Control & Hygiene ISO 16603 / ISO 16604 — Resistance of materials to penetration by blood and body fluids / blood-borne pathogens

EN ISO 22610 — Resistance to wet bacterial penetration (commonly referenced alongside UNI EN 13795)

EN ISO 22612 — Resistance to dry microbial penetration

ISO 14272 (and related) — Cleanability and disinfectant resistance

Flammability Standards (Hospital Safety) BS 7175 — Flammability testing for bed mattresses and components used in hospitals (UK/NHS standard)

Crib 5 / Source 5 test — Specific ignition resistance test (often cited in Australia & UK healthcare tenders)

CAL TB 129 (California Technical Bulletin) — Full-scale flammability test for mattresses

EN 597-1 & EN 597-2 — Smouldering cigarette and match flame tests

Performance & Durability SO 12947 (Martindale Test) — Abrasion resistance of fabrics

ISO 811 — Hydrostatic head test (liquid barrier performance)

ISO 14126 — Protective clothing against infective agents (often adapted for mattress covers in clinical use)

EN 13795 (for surgical textiles, sometimes referenced in infection-barrier bedding)

Resources

WinnCare Resources

 

 

WinnCare product brochures, user guides, certificates and standards, warranties and additional resources and support material available via button link above.

Enquiry

Disclaimer

All product descriptions, indications or advice found on this website are to be used as a guide only, and are by no means a substitute for professional medical advice. Proper use of medical devices requires diagnosis by a physician or physical therapist. Finch Healtchare accepts no responsibility for the improper or uninformed use of it’s products.