Pure Air 120 Mattress
The Pure Air 120 Mattress is a premium dynamic bariatric pressure care system designed for patients at very high risk of pressure injuries, with a safe working load of up to 298 kg. Developed for acute, long-term, and high-dependency care environments, it provides continuous pressure redistribution and stability while addressing the specific challenges of bariatric care.
- Description
- Features
- Mattress Specifications
- Control Unit Specifications
- Warranties & Standards
- Resources
- Enquiry
- Disclaimer
The Pure Air 120 Mattress is a premium dynamic bariatric pressure care system designed for patients at very high risk of pressure injuries, with a safe working load of up to 298 kg. Developed for acute, long-term, and high-dependency care environments, it provides continuous pressure redistribution and stability while addressing the specific challenges of bariatric care.
The mattress features full-width “Figure of 8” air cells with i-Beam reinforcement, creating a stable, shock-absorbing surface that prevents bottoming out and minimises patient sliding during repositioning or transfers. Combined with intelligent semi-automatic adjustment, the system delivers low interface pressures tailored to patient weight, movement, and clinical needs.
A patented alternation cycle ensures smoother, quieter transitions between inflation phases, reducing shear forces and minimising sleep disruption. Configurable cycle times (10 or 15 minutes) allow clinicians to adapt therapy to individual requirements.
The multi-stretch, vapour-permeable cover with high-frequency welded seams supports effective moisture management, infection control, and skin protection. Fully removable and machine washable at 95°C, it meets stringent hygiene protocols across hospital and bariatric care settings.
For safety and efficiency, the Pure Air 120 integrates CPR quick-release, a 24-hour transport mode, and audible low-pressure alarms with a mute function. A panel lock prevents accidental setting changes, ensuring uninterrupted therapy and consistent clinical outcomes.
Features
Key Features:
-
Bariatric dynamic replacement mattress – supports users up to 298 kg.
-
Full-width “Figure of 8” air cells with i-Beam design – provides stability, shock absorption, and prevents bottoming out.
-
Low interface pressure technology – immersion and offloading reduce pressure injury risk in high-risk bariatric patients.
-
Configurable alternation cycle – selectable 10 or 15-minute cycles for tailored therapy.
-
Quiet operation (<40 dB[A]) – minimises patient disturbance, promotes restful sleep.
-
Rapid response features – CPR deflation in under 30 seconds, 24-hour transport mode.
-
Infection control compliant – vapour-permeable, welded cover washable at 95°C.
-
Clinical alarms and safety lock – audible alerts with mute function, control panel lock for therapy adherence.
Mattress Specifications
| Feature | Details |
|---|---|
| Max User Weight | 298 kg |
| Dimensions | 200 cm x 120 cm x 20 cm |
| Number of Cells | 20 alternating |
| Inflated Cell Height | 20 cm |
| Alternation Cycle | 1 in 2 |
| Initial Inflation Time | 30 – 40 mins |
| Cell Material | TPU |
| Internal Cell Pressure | 30 – 60 mmHg |
| Top Cover | Multi-stretch polyurethane |
| Seams | High frequency welded |
| CPR | Pull chord (deflates within 30 seconds) |
| Transport Mode | 24 hours via transport cap |
| Cleaning | Machine washable up to 95°C |
Control Unit Specifications
| Feature | Details |
|---|---|
| Dimensions | 23.5 cm x 35.5 cm x 13.5 cm |
| Weight | 3.7 kg |
| Max Inflate | Auto-return to therapy after 30 mins |
| Cell Cycle Time | 10, 15 mins |
| Pressure Adjustment | Semi-automatic |
| Noise Level | <40 dB(A) |
| Alerts | Audible low pressure alert with mute |
| Control Panel Lock | Yes |
Warranties & Standards
ARTG Number: 363471
Warranty:
| Mattress Internal Components | Three Years |
| Cover | Three Years |
| Pump | Three Years |
| Clinical Service Life – Normal Use | Six Years |
Standards:
| EMDN Code & Term | V080701 Active anti-bedsore medical mattresses |
| Risk Classification | Risk Classification: Class I medical device according to the regulation (EU) 2017/745, Annex VIII, rule 1 |
| Harmonised Standards Applied | EN ISO: 13485:2016, 14971:2012, 15223-1:2016, 10535:2006 |
| Basic UDI-DI | 50564619DYN_PUP3N |
| Quality Management System | ISO-13485-2016 |
| Safety Standards | BS EB 60601-1:2006+A13:2024 IEC 60601-1-11, IEC 60601-1-2, BS EN 61000, IEC 61000-3-3, IEC 61000-3-2, IEC 61000-4-2, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEC 61000-4-8, IEC 61000-4-6, IEC 61000-4-3 |
| Biocompatibility Standards (Skin & Patient Contact) | SO 10993 series — Biological evaluation of medical devices
ISO 10993-1: Evaluation and testing within a risk management process ISO 10993-5: Tests for in vitro cytotoxicity ISO 10993-10: Tests for irritation and skin sensitization ISO 10993-23: Tests for irritation (skin and mucosal surfaces) |
| Infection Control & Hygiene | ISO 16603 / ISO 16604 — Resistance of materials to penetration by blood and body fluids / blood-borne pathogens
EN ISO 22610 — Resistance to wet bacterial penetration (commonly referenced alongside UNI EN 13795) EN ISO 22612 — Resistance to dry microbial penetration ISO 14272 (and related) — Cleanability and disinfectant resistance |
| Flammability Standards (Hospital Safety) | BS 7175 — Flammability testing for bed mattresses and components used in hospitals (UK/NHS standard)
Crib 5 / Source 5 test — Specific ignition resistance test (often cited in Australia & UK healthcare tenders) CAL TB 129 (California Technical Bulletin) — Full-scale flammability test for mattresses EN 597-1 & EN 597-2 — Smouldering cigarette and match flame tests |
| Performance & Durability | SO 12947 (Martindale Test) — Abrasion resistance of fabrics
ISO 811 — Hydrostatic head test (liquid barrier performance) ISO 14126 — Protective clothing against infective agents (often adapted for mattress covers in clinical use) EN 13795 (for surgical textiles, sometimes referenced in infection-barrier bedding) |
Resources
WinnCare product brochures, user guides, certificates and standards, warranties and additional resources and support material available via button link above.
Enquiry
Disclaimer
All product descriptions, indications or advice found on this website are to be used as a guide only, and are by no means a substitute for professional medical advice. Proper use of medical devices requires diagnosis by a physician or physical therapist. Finch Healtchare accepts no responsibility for the improper or uninformed use of it’s products.